HY: Generator/Regulator System
HY: Introduction See: HY: Generator/Regulator System - Introduction
HY1 DTC P1246: VERIFY GENERATOR DRIVE FUNCTION
- Check generator drive belt condition.
- Check generator drive belt tension.
- Start engine, verify generator turning.
Does generator turn?
Yes
.
No
- REFER to Charging System.
HY2 VERIFY CHARGING SYSTEM IS EEC CONTROLLED
- Key off.
- Disconnect battery terminals at battery, and the battery lead to the alternator.
- Disconnect generator harness connector and measure resistance between battery-sense and gen-com pin at the generator.
Is resistance between 950 and 1050 ohms?
Yes
.
No
- REPLACE generator/regulator assembly.
HY3 CHECK BATTERY-SENSE VOLTAGE AT BATTERY
- Note: When checking voltage of the battery sense circuit at the alternator, it may be necessary to clean and or tighten the connector nut.
- Reconnect generator.
- Reconnect battery.
Is battery voltage at battery-sense circuit pin at the generator/regulator harness connector within plus or minus 0.5 volt of battery voltage?
Yes
.
No
- REPAIR battery-sense circuit.
HY4 CHECK GENERATOR FAILURE MODE
- All electrical load off.
- Access the GFSF PID.
- Increase engine speed to 2,000 rpm.
- Perform wiggle test.
Is a failure indicated?
Yes
.
No
- REFER to Charging System.
HY5 CHECK GEN-MON AND GEN-COM CIRCUIT FOR SHORT TO POWER
- Key off.
- PCM and generator/regulator disconnected.
- Key on.
- Measure voltage between gen-com signal pin at the PCM harness connector and chassis ground.
- Measure voltage between gen-mon signal pin at the PCM harness connector and chassis ground.
Is each voltage greater than 0.5 volt?
Yes
- KEY OFF. REPAIR short circuit.
No
.
HY6 CHECK GEN-MON AND GEN-COM CIRCUIT FOR SHORT TO GROUND
- Measure resistance between the gen-com signal pin at the PCM harness connector and chassis ground.
- Measure resistance between the gen-mon signal pin at the PCM harness connector and chassis ground.
Is resistance greater than 10,000 ohms?
Yes
.
No
HY7 CHECK GEN-MON AND GEN-COM CIRCUIT FOR OPEN
- Measure resistance of the gen-com circuit between the generator/regulator harness connector and the PCM harness connector.
- Measure resistance of the gen-mon circuit between the generator/regulator connector and the PCM harness connector.
Is each resistance less than 5.0 ohms?
Yes
.
No
HY8 CHECK GENERATOR MONITOR SIGNAL
- Engine idling.
- Access GFS PID.
Is duty cycle between 6-98%?
Yes
.
No
- REPLACE generator/regulator assembly.
HY9 CHECK GENERATOR COMMUNICATOR SIGNAL
- Access GENFDC PID.
- Engine idling.
- Toggle load on and off (headlights).
Does PID switch within 0-99% range?
Yes
,
intermittent circuit failure diagnosis.
No
|