KQ: Thermostat Heater Control (THTRC)
KQ: Introduction See: KQ: Thermostat Heater Control (THTRC) - Introduction
KQ10 DTC P1432: CHECK VPWR AT THTRC HARNESS CONNECTOR
Note: Refer to the PCM connector pin numbers in the beginning of this pinpoint test.
- Disconnect the thermostat harness connector.
- Key on.
- Measure VPWR circuit voltage at THTRC harness connector.
Is the voltage reading greater than 10.5 volts?
Yes
.
No
- KEY OFF. REPAIR VPWR circuit.
KQ11 CHECK THERMOSTAT RESISTANCE
- Measure resistance of the thermostat at the two pin terminal connector.
Is resistance between 14.0 and 16.0 ohms?
Yes
.
No
KQ12 CHECK THTRC CIRCUIT FOR OPEN IN HARNESS
- Disconnect PCM.
- Measure resistance between THTRC circuit between PCM harness connector pin and the THTRC harness connector.
Is the resistance less than 5.0 ohms?
Yes
.
No
KQ13 CHECK THTRC CIRCUIT FOR SHORT TO GROUND OR VPWR IN HARNESS
- Measure resistance between THTRC PCM pin and PCM pins VPWR, SIG RTN and PWR GND.
Is each resistance greater than 10,000 ohms?
Yes
- For Continuous DTC P1432 only,
GO to Z1 See: Diagnostic Trouble Code Tests and Associated Procedures\SECTION 5: Pinpoint Tests\Z: Intermittent - Pinpoint Test
.
- For KOEO or KOER DTC P1432,
REPLACE PCM.
No
- REPAIR short to GND or VPWR.
|