REMOVAL

  

  1. Disconnect the battery ground cable.

  

  1. Remove the three retainers and the RH Cowl side trim panel.

  

  1. If equipped, detach the power door lock relay.

  

  1. Disconnect the daytime running lamp control module electrical connector.

  

  1. Detach the daytime running lamps control module from the DRL bracket.

INSTALLATION

  1. To install, reverse the removal procedure.

NOTE : When the battery is disconnected and reconnected, some abnormal drive symptoms may occur while the vehicle relearns its adaptive strategy. The vehicle may need to be driven 16 km (10 mi) or more to relearn the strategy.