DQ: Barometric Pressure (BARO) Sensor
DQ: Introduction See: DQ: Barometric Pressure (BARO) Sensor - Introduction
DQ1 DTC P0106, P0107, P0108 AND P0109: CHECK BARO PID
- Obtain local barometric pressure reading.
- Access BARO PID.
- Compare PID readings with chart.
Does PID reading compare with that of chart?
Yes
.
No
.
DQ2 CHECK BARO SIGNAL AND SIG RTN CIRCUIT FOR OPEN
- Measure resistance of the BARO circuit between PCM harness connector pin and BARO sensor harness connector.
- Measure resistance of the SIG RTN circuit between PCM harness connector pin and SIG RTN at the BARO sensor harness connector.
Is each resistance less than 5.0 ohms?
Yes
.
GO to DQ7
.
No
DQ3 CHECK VREF VOLTAGE TO BARO SENSOR
- Disconnect BARO connector.
- Measure voltage between VREF and SIG RTN circuits at the BARO harness connector.
Is VREF voltage between 4.0 and 6.0 volts?
Yes
.
No
.
DQ4 CHECK VREF CIRCUIT FOR OPEN
- Measure resistance of the VREF circuit between PCM harness connector pin and VREF at the BARO sensor harness connector.
Is resistance less than 5.0 ohms?
Yes
.
No
DQ5 CHECK BARO CIRCUIT FOR SHORT TO GROUND
- Measure resistance between the BARO and SIG RTN circuits at the PCM harness connector.
- Measure resistance between the BARO circuit at the PCM harness connector and the battery negative post.
Is each resistance greater than 10,000 ohms?
Yes
.
No
DQ6 CHECK FOR VREF CIRCUIT SHORT TO GROUND
- Measure resistance between the VREF circuit and SIG RTN circuits at the PCM harness connector.
- Measure resistance between the VREF circuit at the PCM harness connector and the battery negative post.
Is each resistance greater than 10,000 ohms?
Yes
No
DQ7 DTC P0108: INDUCE OPPOSITE CODE
- Disconnect BARO sensor.
- Key on.
- Check DTCs.
Is DTC P0107 present?
Yes
- KEY OFF. REPLACE BARO sensor.
No
.
DQ8 CHECK BARO SIGNAL FOR SHORT TO POWER
- Measure resistance between BARO and VPWR circuits at the PCM harness connector.
Is each resistance greater than 10,000 ohms?
Yes
No
|