Your Vehicle: 2001 Ford Escort ZX2 L4-2.0L DOHC VIN 3
 
Vehicle » Powertrain Management » Emission Control Systems » EGR Valve » Description and Operation » Differential Pressure Feedback EGR  
 
 
  Differential Pressure Feedback EGR  
 

EXHAUST GAS RECIRCULATION VALVE

EGR Valve
  

Test Graph
  

The EGR valve (Figure 89) in the Differential Pressure Feedback EGR system is a conventional, vacuum-actuated EGR valve. The valve increases or decreases the flow of exhaust gas recirculation. As vacuum applied to the EGR valve diaphragm overcomes the spring force, the valve begins to open. As the vacuum signal weakens, at 5.4 kPa (1.6 in-Hg) or less, the spring force closes the valve. The EGR valve is fully open at about 15 kPa (4.5 in-Hg) .

Since EGR flow requirement varies greatly, providing service specifications on flow rate is impractical. The on-board diagnostic system monitors the EGR valve function and triggers a Diagnostic Trouble Code if the test criteria is not met. The EGR valve flow rate is not measured directly as part of the field diagnostic procedures.