Your Vehicle: 2001 Ford Escort ZX2 L4-2.0L DOHC VIN 3
 
Vehicle » Powertrain Management » Computers and Control Systems » Testing and Inspection » Scan Tool Testing and Procedures » Output Test Mode  
 
 
  Output Test Mode  
 

Output Test Mode
Description
The Output Test Mode (OTM) aids in servicing output actuators associated with the PCM. This mode allows the technician to energize and de-energize most of the system output actuators on command. When entering OTM, the outputs can be turned off and on without activating the fan control. The low and high speed fan control(s) may be turned on separately without energizing the other outputs. This function is supported by each vehicle strategy and may not be available on all scan tools.
As a safety precaution, Output Test Mode will default to the off state after 10 minutes and fuel pump off after approximately 7-10 seconds. OTM will also turn off after the vehicle is started or after cycling the key off then on.
WARNING:SAFETY MUST BE OBSERVED WHEN USING OUTPUT TEST MODE:

  • WHEN ALL OUTPUTS ARE ON, THE ELECTRIC FUEL PUMP IS BRIEFLY ENERGIZED, SO MAKE SURE FUEL SYSTEM IS INTACT AND IS NOT BEING SERVICED AT THIS TIME.
  • WHEN LOW SPEED OR HIGH SPEED FAN CONTROL(S) ARE TURNED ON, MAKE SURE FAN BLADES ARE CLEAR OF ANY OBSTRUCTION.