Controls the trunk room lamp (ground side) to turn the trunk room lamp ON and OFF.
TRUNK ROOM LAMP CIRCUIT
Diagnosis Procedure
1.CHECK TRUNK ROOM LAMP OUTPUT
CONSULT-III
Turn ignition switch ON.
Select "LUGGAGE LAMP TEST" of BCM (INT LAMP) active test item.
While operating the test item, check voltage between BCM connector M20 terminal 110 and ground.
Is the Inspection result normal?
YES >> Trunk room lamp circuit is operating normally.
Fixed ON>>GO TO 3
Fixed OFF>>GO TO 2 2.CHECK TRUNK ROOM LAMP OPEN CIRCUIT
Turn ignition switch OFF.
Disconnect BCM connector M20 and trunk room lamp connector.
Check continuity between BCM connector M20 (A) terminal 110 and trunk room lamp connector B36 (B) terminal 2.