This bulletin has been amended. The APPLIED VEHICLES section has been revised. No other changes have been made. Please discard all previous versions of this bulletin.
APPLIED VEHICLES: 2009 2011 370Z Coupe (Z34)
2007-2011 Altima Sedan and Hybrid (L32 and L32HV)
2008-2011 Altima Coupe (CL32)
2009-2011 Maxima (A35)
2009-2011 Murano (Z51)
2008-2011 Rogue (535)
2007-2011 Sentra (B16)
2007-2011 Versa (C11)
IF YOU CONFIRM
A power window "Auto Up" will not work.
ACTIONS
Perform the following initialization procedure:
1. Close the door.
2. Turn the ignition switch ON.
3. Open the window-all the way DOWN.
4. Pull all the way UP on the switch and hold (close the window).
^
Continue holding the switch all the way UP for 4 seconds after the window is closed.
5. Confirm the window is now operating correctly.
NOTES:
^
If the window is still not operating correctly, refer to ASIST and the Service Manual for further diagnosis and repair information.
^
The above initialization procedure must be performed if any of the following occur:
>
Battery cable is disconnected.
>
Power window switch connector is disconnected.
>
Power window regulator is replaced.
>
Power window motor is replaced.
>
Window glass is removed.
>
Window glass run rubber is replaced.
>
Power window fuse is blown.
>
Window is partly opened and/or closed many times without being fully closed.