Your Vehicle: 2009 Nissan-Datsun Altima V6-3.5L (VQ35DE)
 
Vehicle » Powertrain Management » Computers and Control Systems » Oxygen Sensor » Technical Service Bulletins » Engine Controls - Seized O2 Sensor Removal Procedure » Service Procedure  
 
 
  Service Procedure  
 

Rust Penetrant

  

Recommended rust penetrants to be used in this procedure:

NOTES:
^ Rust penetrant is considered a shop supply.

^ Nissan Rust Penetrant can be ordered through the Nissan Direct Ship Chemical Care Product Program, Website order via link on dealer portal.

^ WD-40 is available from various local sources.

Removal Tool

  

^ When removing a seized exhaust sensor with a specialty socket (which contains a slit to accommodate the wiring harness), it may spread open and strip the sensor.

^ Before this occurs, it is recommended to cut the wiring harness from the sensor and use a box end wrench or 6-point deep well socket.

1. Clamp the exhaust manifold/catalyst/front tube in a vice.

  

2. Spray the sensor with the rust penetrant for 2 to 3 seconds.

^ It is important that the spray is directed at the base of the sensor to ensure it penetrates into the threads.

  

3. Loosen the sensor approximately 10 degrees.

4. Spray with rust penetrant again for 2 to 3 seconds.

  

5. Tighten the sensor 10 degrees, then loosen the sensor 10 degrees.

^ Repeat this motion several times until the sensor begins to turn more easily.

6. Continue the tightening/loosening motion while gradually unscrewing the sensor. Stop when the sensor will not unscrew any further.

  

7. Spray with rust penetrant again for 2 to 3 seconds.

8. Repeat steps 6 and 7 until the sensor is removed.

  

9. Use compressed air to remove any metal debris from inside the boss threads.

CAUTION:
DO NOT perform this step if the procedure is being done on the vehicle (Method #1). Doing so may cause metal debris to enter the engine cylinders.

  

10. If metal debris remains trapped in the boss threads, use a spiral nylon brush to remove it.

11. Spray the boss threads with rust penetrant for 2 to 3 seconds.

  

12. Run a thread chaser through the boss to clean the threads.

^ Use Kent Moore part number J-43897-18 or J43897-12.

  

13. Use compressed air to remove any remaining debris.

CAUTION:
DO NOT perform this step if the procedure is being done on the vehicle (Method #1). Doing so may cause metal debris to enter the engine cylinders.

14. If metal debris remains trapped in the boss threads, use a spiral nylon brush to remove it.

15. Tilt the manifold/catalyst/front tube so that the metal debris falls out of the part.

16. Apply compressed air through the boss to blow out any remaining debris.

CAUTION:
DO NOT perform this step if the procedure is being done on the vehicle (Method #1). Doing so may cause metal debris to enter the engine cylinders.

17. Install the new sensor as described in the applicable Electronic Service Manual (ESM).