Intake valve timing control solenoid valve is activated by ON/OFF pulse duty (ratio) signals from the ECM.
The intake valve timing control solenoid valve changes the oil amount and direction of flow via the intake valve timing control unit or stops oil flow.
The longer pulse width advances valve timing.
The shorter pulse width retards valve timing.
When ON and OFF pulse widths become equal, the solenoid valve stops oil pressure flow to fix the intake valve angle at the control position.
DTC Logic
DTC DETECTION LOGIC
DTC CONFIRMATION PROCEDURE 1.PRECONDITIONING
If DTC Confirmation Procedure has been previously conducted, always perform the following before conducting the next test.
Turn ignition switch OFF and wait at least 10 seconds.
Turn ignition switch ON.
Turn ignition switch OFF and wait at least 10 seconds. >> GO TO 2.
2.PERFORM DTC CONFIRMATION PROCEDURE
Start engine and let it idle for 5 seconds.
Check 1st trip DTC. Is 1st trip DTC detected?
YES >> Go to Diagnosis Procedure.
NO >> Inspection END
Diagnosis Procedure 1.CHECK INTAKE VALVE TIMING CONTROL SOLENOID VALVE POWER SUPPLY CIRCUIT
Turn ignition switch OFF.
Disconnect intake valve timing (IVT) control solenoid valve harness connector.
Turn ignition switch ON.
Check the voltage between intake valve timing control solenoid valve harness connector and ground with CONSULT-III or tester.
Is the Inspection result normal?
YES >> GO TO 2.
NO >> Repair open circuit, short to ground or short to power in harness or connectors. 2.CHECK INTAKE VALVE TIMING CONTROL SOLENOID VALVE OUTPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
Turn ignition switch OFF.
Disconnect ECM harness connector.
Check the continuity between intake valve timing control solenoid valve harness connector and ECM harness connector.
Also check harness for short to ground and short to power. Is the Inspection result normal?
Component Inspection 1.CHECK INTAKE VALVE TIMING CONTROL SOLENOID VALVE-I
Disconnect intake valve timing control solenoid valve harness connector.
Check resistance between intake valve timing control solenoid valve terminals as per the following.
Is the Inspection result normal?
YES >> GO TO 2.
NO >> Replace malfunctioning intake valve timing control solenoid valve. 2.CHECK INTAKE VALVE TIMING CONTROL SOLENOID VALVE-II
Remove intake valve timing control solenoid valve.
Provide 12 V DC between intake valve timing control solenoid valve terminals 1 and 2, and then interrupt it. Check that the plunger moves as shown in the figure.
CAUTION: Never apply 12 V DC continuously for 5 seconds or more. Doing so may result in damage to the coil in intake valve timing control solenoid valve.
NOTE: Always replace O-ring when intake valve timing control solenoid valve is removed.
Is the Inspection result normal?
YES >> Inspection END
NO >> Replace malfunctioning intake valve timing control solenoid valve.