The EVAP control system pressure sensor detects pressure in the purge line. The sensor output voltage to the ECM increases as pressure increases.
DTC Logic
DTC DETECTION LOGIC
DTC CONFIRMATION PROCEDURE 1.PRECONDITIONING
If DTC Confirmation Procedure has been previously conducted, always perform the following before conducting the next test.
Turn ignition switch OFF and wait at least 10 seconds.
Turn ignition switch ON.
Turn ignition switch OFF and wait at least 10 seconds. TESTING CONDITION:
Always perform test at a temperature of 5°C (41°F) or more.
>> GO TO 2. 2.PERFORM DTC CONFIRMATION PROCEDURE With CONSULT-III
Start engine and warm it up to normal operating temperature.
Turn ignition switch OFF and wait at least 10 seconds.
Turn ignition switch ON.
Turn ignition switch OFF and wait at least 10 seconds.
Turn ignition switch ON.
Select "DATA MONITOR" mode with CONSULT-III.
Check that "FUEL T/TMP SE" is more than 0°C (32°F) .
Start engine and wait at least 20 seconds.
Check 1st trip DTC. With GST
Start engine and warm it up to normal operating temperature.
Set voltmeter probes to ECM harness connector terminals under the following conditions.
Check that the voltage is less than 4.2 V.
Turn ignition switch OFF and wait at least 10 seconds.
Turn ignition switch ON.
Turn ignition switch OFF and wait at least 10 seconds.
Start engine and wait at least 20 seconds.
Check 1st trip DTC. Is 1st trip DTC detected?
YES >> Go to Diagnosis Procedure.
NO >> Inspection END
YES >> GO TO 2.
NO >> Repair or replace ground connection. 2.CHECK CONNECTOR
Disconnect EVAP control system pressure sensor harness connector.
Check that water is not inside connectors. Is the Inspection result normal?
YES >> GO TO 3.
NO >> Repair or replace harness connector. 3.CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR POWER SUPPLY CIRCUIT-I
Turn ignition switch ON.
Check the voltage between EVAP control system pressure sensor harness connector and ground.
Is the Inspection result normal?
YES >> GO TO 10.
NO >> GO TO 4. 4.CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR POWER SUPPLY CIRCUIT-II
Turn ignition switch OFF.
Disconnect ECM harness connector.
Check the continuity between EVAP control system pressure sensor harness connector and ECM harness connector.
Is the Inspection result normal?
YES >> GO TO 6.
NO >> GO TO 5. 5.DETECT MALFUNCTIONING PART
Check the following.
Harness connectors B10, E29
Harness for open or short between EVAP control system pressure sensor and ECM >> Repair open circuit.
6.CHECK SENSOR POWER SUPPLY CIRCUIT
Check harness for short to power and short to ground, between the following terminals.
Is the Inspection result normal?
YES >> GO TO 7.
NO >> Repair short to ground or short to power in harness or connectors. 7.CHECK COMPONENTS
Check the following.
Crankshaft position sensor (POS) (Refer to See: P0335.)
YES >> GO TO 8.
NO >> Replace malfunctioning components. 8.CHECK APP SENSOR
Refer to See: P2122.
Is the Inspection result normal?
YES >> GO TO 15.
NO >> GO TO 9. 9.REPLACE ACCELERATOR PEDAL ASSEMBLY
10.CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR GROUND CIRCUIT FOR OPEN AND SHORT
Turn ignition switch OFF.
Disconnect ECM harness connector.
Check the continuity between EVAP control system pressure sensor harness connector and ECM harness connector.
Also check harness for short to ground and short to power. Is the Inspection result normal?
YES >> GO TO 12.
NO >> GO TO 11. 11.DETECT MALFUNCTIONING PART
Check the following.
Harness connectors B10, E29
Harness for open or short between EVAP control system pressure sensor and ECM >> Repair open circuit, short to ground or short to power in harness or connectors.
12.CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
Check the continuity between EVAP control system pressure sensor harness connector and ECM harness connector.
Also check harness for short to ground and short to power. Is the Inspection result normal?
YES >> GO TO 14.
NO >> GO TO 13. 13.DETECT MALFUNCTIONING PART
Check the following.
Harness connectors B10, E29
Harness for open or short between EVAP control system pressure sensor and ECM >> Repair open circuit, short to ground or short to power in harness or connectors.