TCS OFF switch can deactivate (turn OFF) the TCS function by pressing the TCS OFF switch.
TCS OFF SWITCH
Diagnosis Procedure
Inspection PROCEDURE 1.CHECK TCS OFF SWITCH
Perform the TCS OFF switch component Inspection. Refer to See: Component Inspection.
Is the Inspection result normal?
YES >> GO TO 2
NO >> Replace TCS OFF switch. 2.CHECK TCS OFF SWITCH HARNESS
Disconnect ABS actuator and electric unit (control unit) connector E26.
Check continuity between ABS actuator and electric unit (control unit) connector E26 (A) terminal 13 and TCS OFF switch connector M72 (B) terminal 1.
Check continuity between ABS actuator and electric unit (control unit) connector E26 (A) terminal 13 and ground.
Is the Inspection result normal?
YES >> GO TO 3
NO >> Repair or replace malfunctioning components. 3.CHECK TCS OFF SWITCH GROUND
Check continuity between TCS OFF switch connector M72 terminal
2 and ground.
Is the Inspection result normal?
YES >> Inspection end.
NO >> Repair or replace malfunctioning components.