Inspection AND ADJUSTMENT
ADDITIONAL SERVICE WHEN REMOVING BATTERY NEGATIVE TERMINAL : Special Repair Requirement
INITIALIZATION PROCEDURE
- Disconnect battery negative terminal or main power window and door lock/unlock switch. Reconnect it after a minute or more.
- Turn ignition switch ON.
- Operate power window switch to fully open the window. (This operation is unnecessary if the window is already fully open)
- Continue pulling the power window switch UP (AUTO-UP operation). Even after glass stops at fully closed position, keep pulling the switch for 4 seconds or more.
- Inspect anti-pinch function.
CHECK ANTI-PINCH FUNCTION
- Fully open the door window.
- Place a piece of wood near fully closed position.
- Close door glass completely with AUTO-UP.
- Check that glass lowers for approximately 150 mm or 2 seconds without pinching piece of wood and stops.
- Check that glass does not rise when operating the power window main switch while lowering.
CAUTION:
- Do not check with hands and other part of body because they may be pinched. Do not get pinched.
- Check that AUTO-UP operates before Inspection when system initialization is performed.
- It may switch to fail-safe mode if open/close operation is performed continuously. Perform initial setting in that situation. Refer to See: Initial Inspection and Diagnostic Overview\Fail Safe\Power Window Main Switch\LH & RH Front Anti-Pinch-Coupe.
- Perform initial setting when auto-up operation or anti-pinch function does not operate normally.
- Finish initial setting. Otherwise, next operation cannot be done. 1. Auto-up operation
2. Anti-pinch function
3. Retained power operation when ignition switch is OFF.
|