Your Vehicle: 2009 Nissan-Datsun Altima V6-3.5L (VQ35DE)
 
Vehicle » Starting and Charging » Charging System » Service Precautions » Vehicle Damage Warnings » Precaution For Power Generation Voltage Variable Control System  
 
 
  Precaution For Power Generation Voltage Variable Control System  
 

PRECAUTIONS

Precaution for Power Generation Voltage Variable Control System

CAUTION:
For this model, the battery current sensor that is installed to the battery cable at the negative terminal measures the charging/discharging current of the battery, and performs various controls. If the electrical component or the ground wire is connected directly to the battery terminal, the current other than that being measured with the battery current sensor is charging to or discharging from the battery.
This condition causes the malfunction of the control, and then the battery discharge may occur. Do not connect the electrical component or the ground wire directly to the battery terminal.