Check if terminal "1" is clean and tight. Is the Inspection result normal?
YES >> GO TO 2
NO >> Repair terminal "1" connection. Confirm repair by performing complete Starting/Charging system test. Refer to Technical Service Bulletin. 2.CHECK TERMINAL "1" CIRCUIT
Check voltage between generator connector F6 terminal 1 and ground.
1 - ground Battery voltage
Is the Inspection result normal?
YES >> GO TO 3
NO >> Check harness for open between generator and fusible link. 3.CHECK TERMINAL "1" CONNECTION (VOLTAGE DROP TEST)
Start engine, then engine running at idle and warm.
Check voltage between battery positive terminal and generator connector F6 terminal 1.