The terminal "2" (L) circuit controls the charge warning lamp. The charge warning lamp illuminates when the ignition switch is set to ON or START. When the generator is providing sufficient voltage with the engine running, the charge warning lamp will go off. If the charge warning lamp illuminates with the engine running, a malfunction is indicated.
L TERMINAL CIRCUIT
Diagnosis Procedure
1.CHECK CHARGE WARNING LAMP CIRCUIT CONNECTION
Check to see if generator connector F7 terminal 2 is clean and tight.
Is the connection secure?
YES >> GO TO 2
NO >> Repair the connection. Confirm repair by performing complete Starting/Charging system test. Refer to Technical Service Bulletin. 2.CHECK CHARGE WARNING LAMP CIRCUIT
Disconnect generator connector F7.
Apply ground to generator harness connector F7 terminal 2 with the ignition switch in the ON position.