MEMORY FUNCTION DOES NOT OPERATE
Diagnosis Procedure
SYMPTOM: Memory function does not operate. The setting is not maintained (it returns to the initial condition).
Inspection procedure
1.CHECK OPERATION
- Set temperature control dial to 32°C (90°F) .
- Press OFF switch.
- Press ignition switch OFF.
- Press ignition switch ON.
- Press AUTO switch.
- Check that the set temperature is maintained. Is the Inspection result normal?
YES >> Inspection End.
NO >> GO TO 2.
2.CHECK POWER SUPPLY AND GROUND CIRCUIT OF FRONT AIR CONTROL
Check power supply and ground circuit of front air control. Refer to See: Component Tests and General Diagnostics\Power Supply And Ground Circuit\Diagnosis Procedure\Automatic Air Conditioner.
Is the Inspection result normal?
YES >> Replace front air control. Refer to See: Control Module HVAC\Service and Repair.
NO >> Repair or replace malfunctioning part(s).
|