MAGNET CLUTCH
Component Function Check
Inspection FLOW
CONFIRM SYMPTOM BY PERFORMING OPERATION CHECK - MAGNET CLUTCH
Press ignition switch ON.
Press vent switch ( ).
Press A/C switch.
Confirm that the A/C compressor clutch engages (sound or visual Inspection). (Discharge air and blower speed will depend on ambient, in-vehicle and set temperatures). Can a symptom be duplicated? YES >> GO TO 3
NO >> GO TO 2
PERFORM COMPLETE OPERATIONAL CHECK Perform a complete operational check and check for any symptoms. Refer to See: Initial Inspection and Diagnostic Overview\Inspection And Adjustment\Description And Conditions\Automatic Air Conditioner . Is the Inspection result normal?
YES >> Refer to See: Symptom Related Diagnostic Procedures\Automatic Air Conditioner System\Symptom Matrix Chart .
NO >> System OK.
CHECK FOR SERVICE BULLETINS Check for any service bulletins. >> GO TO 4
CHECK MAGNET CLUTCH MECHANISM Check for magnet clutch operation. Does the magnet clutch engage?
YES >> GO TO 5
NO >> Check magnet clutch circuit. Refer to See: Diagnosis Procedure\Automatic Air Conditioner .
CHECK AMBIENT SENSOR CIRCUIT Perform diagnostic procedure for the mode door motor. Refer to See: Mode Door\Automatic Air Conditioner . Is the Inspection result normal?
YES >> GO TO 6
NO >> Repair as necessary.
CHECK IN-VEHICLE SENSOR CIRCUIT Perform diagnostic procedure for the in-vehicle sensor circuit. Refer to See: In-Vehicle Sensor\Diagnosis Procedure . Is the Inspection result normal?
YES >> GO TO 7
NO >> Repair as necessary.
CHECK SUNLOAD SENSOR CIRCUIT Perform diagnostic procedure for the sunload sensor circuit. Refer to See: Sunload Sensor\Diagnosis Procedure . Is the Inspection result normal?
YES >> GO TO 8
NO >> Repair as necessary.
CHECK INTAKE SENSOR CIRCUIT Perform diagnostic procedure for the intake sensor circuit. Refer to See: Intake Sensor\Diagnosis Procedure . Is the Inspection result normal?
YES >> GO TO 9
NO >> Repair as necessary.
CHECK AIR MIX DOOR MOTOR PBR CIRCUITS Perform diagnostic procedure for the air mix door motor circuit. Refer to See: Air Mix Door\Automatic Air Conditioner . Is the Inspection result normal?
YES >> GO TO 10
NO >> Repair as necessary.
RECHECK FOR SYMPTOMS Perform a complete operational check and check for any symptoms. Refer to See: Initial Inspection and Diagnostic Overview\Inspection And Adjustment\Description And Conditions\Automatic Air Conditioner . Does another symptom exist?
YES >> Repair as necessary.
NO >> Replace front air control. Refer to See: Control Module HVAC\Service and Repair .